COM-3700高精度空气负离子监测器
COM-3700 Air Ion Counter
Large ion counter
5.3800 ~ 0.00269 c㎡/V・sec (2000 Steps Electric mobility)
Earthquake prediction air ion measuring instrument
The atmospheric ion counters of our company are the highly efficient products which use the "double cylinder pipe electrode" used by a scientific area of research. The "double cylinder pipe electrode" is said for an electric field to have few turbulent flows of uniformity and air. The positive ion and the negative ion which exist in natural environment can be measured by the highly efficient sensor of COM-3700. Ion measurement of the various products which generate ion.Indoor ion distribution.In order to use it in various fields, such as ion measurement of natural environment, the personal computer output has. |

|
Measurement system | The Gerdien capacitor method |
Measurement |
There are two kinds of measurement modes, automatic measurement and manual measurement, and it chooses according to a use and can measure. ■ Automatic measurement : A positive ion and negative ion are measured automatically and the display output of the measured value is carried out. ■ Manual measurement : A positive ion and an anion are measured individually and the display output of the measured value is carried out. |
Time base range |
Positive ion, Negative 0-5,000,000 1 piece/cc Measurement range : R1= 0 - 8,000 ion/cc R2= 0 - 50,000 ion/cc R3= 0- 500,000 ion/cc R4= 0 - 5,000,000 ion/cc |
Display for indication | Character 16-figure liquid crystal of two lines The display for indication of a STN system liquid crystal, and back light with an ON/OFF control facility |
Clock function | The built-in clock which had a function of - part and a second at the time of year, moon, and day - is used. |
Memory function |
In order to carry out a memory, there are two kinds, automatic mode and a manual mode. 500 data can be saved. ■ Automatic memory : A memory is carried out with arbitrary time preset values. A preset value is 1, 2, 3, 4, 5, 10, 15, 20, 30, and 60 minutes. (It synchronizes with a built-in clock 5 minutes or more) ■ Manual memory : A memory is carried out to the arbitrary time under measurement by "MEMORY switch" setup. |
Analog output |
■ Analog output 1 (OUT1) : The measurement range under measurement, (0-1V) An analog recorder, a data recorder ■ Analog output 2 (OUT2) : The output range of R1, R2, R3, and R4 is set up. (0-1V) An analog recorder, a data recorder |
Serial communication (RS-232C) |
Data is outputted to external apparatus, such as a personal computer, in real time. It can be used for an external monitor etc. A set period is 1, 5, 10, 15, 20, 30, and 60 seconds. |
Personal computer output | The data which carried out the memory can be outputted to a personal computer in the Excel form. |
Printer output | Drawing of data and digital printing are performed to a thermal printer. |
Electric mobility | 5.3800 ~ 0.00269 c㎡/V・sec (2000 Steps Electric mobility) |
Power supply | DC12V ±10% (Power supply protection fuse 2A) |
Temperature sensor | Time base range: 0 - 50 ℃ Accuracy: 1 ℃ |
Humidity Sensor | Time base range: 5% - 95% Accuracy: 5% |
Ion measurement | 5 ~ 35 ℃ 85%RH ≧ (Don't dew) |
Main part |
size: 130mm x 260mm x 340mm (A projection thing is not included) weight : About 7 kg |
Detector |
size: 160mm x140mm x 720mm (A projection thing is not included) weight : About 8 kg |
Apparatus composition |
Main part, Detector, Connecting cable (5 m) = 2, Cable for temperature humidity (5 m), Data collection display PC software, RS-232C connecting cable, Main part aluminum suitcase, Detector aluminum suitcase, AC power supply Adapter(use power-supply range: AC100-240V), Operation manual |